2024 Kubota Engines GL Series 14000

2024 Kubota Engines GL Series 14000

Swipe to View More

  • Year 2024
  • Make Kubota Engines
  • Model GL Series
  • Engine Model: D902
2024 Kubota Engines GL Series 14000

2024 Kubota Engines GL Series 14000

2024 Kubota Engines GL Series 14000

The GL Series

At the heart of the LOWBOY Series are vertical type SUPER MINI diesel engines, the Z482, D722 and D902. These Tier 4 Final emission certified engines make the generators environmentally friendly while keeping their compact and low body design.

Features may include:

Compact Design
  • Kubota LOWBOY generators have the lowest-possible height while using Kubota’s very own SUPER MINI engines. Compared to other generators, they’re lightweight, require less space for operation, and have a broader range of possible applications.
Easy Maintenance
  • One-side maintenance to reduce the operator’s work load allowing for maintenance checks for oil, fuel, battery and cooling water levels.
Wide Application
  • An access terminal to connect to ATS (Automatic Transfer Switches) is standard equipment. Applicable for stationary use as well.

Engine

Engine Manufacturer Kubota
Engine Model: D902
Rated Engine Speed 3600 rpm
Emissions EPA Tier 4 Final, CARB

Fuel System

Fuel Usage, 100% Load 1.29 gal./h (4.9 L/h) | At 3/4 Load: 1.03 gal./h (3.9 L/h) | At 1/2 Load: 0.85 gal./h (3.2 L/h) | At: 1/4 Load: 0.66 gal./h (2.5 L/h)

Electric

Electrical Frequency: 60 Hz | Rated Voltage: 240 / 120 V | Rated Current: 100 A | Phase / Wire: 1-3 | Power Factor: 1.0 | Frequency Regulation: 0.25 % | Voltage Regulation: 240V: ±0.5 / 120V: ±5.0 % | Voltage Adjusting Range: -15%~+5% of the rated voltage | Momentary Load Variability % Fluctuation rate of the maximum voltage: 30% / Within 3% of the setting voltage Recovery time: 2 seconds | Waveform Distortion Factor (at no load): 2.0 % | Minimum Insulation Resistance: 3 Ohm | Withstand Voltage Test Procedure: 1500V, within 1 minute
Generator Output Rated: 12 kVA | Maximum: 14 kVA | Terminal Block: Single phase - 3 wires (U-N/G-W) / Terminal Size: M8
Receptacles 120V-20A GFCI x 2 (4 receptacles) / 120/240V-50A Twist type x 1

Operational

Run Time Per Tankful Full Load: 7.0 h | At 3/4 Load: 9.0 h | At 1/2 Load: 11.0 h | At: 1/4 Load: 15.0 h

Performance

Noise Level Noise Level (No Load / Rated Operation): 65 / 67 (dB • A/7 m)

Lights and Safety

Safety Features Engine Shut-Off: Low Oil Pressure, Excessive Coolant Temperature, Improper Charging, Over Revolution | Emergency Stop System: Opening of control panel or terminal cover

Dimensions

Length 51.57 in. (1310 mm)
Width 25.2 in. (640 mm)
Height 35.24 in. (895 mm)

Capacities

Oil capacity Spill Containment Capacity: 82 L (186% of the entire fuel, oil and coolant)
Fuel Capacity 9.62 gal. (36.4 L)

Weights

Dry Weight Net: 904 lbs. (410 kg) / 1003 lbs. (455 kg)

Features

Features Breaker: Main x 1 Secondary In-line x2

Product Photography